Type J - Adjustable

Hot dip galvanised post shoes capable of being adjusted to suit different widths


Applications - M12 Holes

  1. Fix two anchors through the base plate to concrete.
  2. Ensure anchor fixing and footing detail are adequate enough to resist the wind load upward and dead plus live load downward.
  3. Fix timber post to steel post anchor with 2/M10 bolts for BPAJ85 or 2/M12 bolts for BPAJ200.

Note Timber posts must sit on Post Anchor metal base plate.

Termite Protection
When installed as per this document, this post anchor provides a vertical inspection zone of 75mm between base of timber and top surface of footing in accordance with AS3660.1.

Where this inspection zone has not been achieved, alternative methods of termite protection may be required.

Embedment Depth
Supporting slab to be designed by others.

Product Specification

Product Code

85mm Leg Length - 2 Piece - M10 Holes - Hot Dipped Galvanised BPAJ85

Material Specification

 
Thickness: 5.0mm
Material: Hot dipped galvanised corrosion protection

Product Specification

Product Code

200mm Leg Length - 2 Piece - M12 Holes - Hot Dipped Galvanised BPAJ200

Material Specification

 
Thickness: 6.0mm
Material: Hot dipped galvanised corrosion protection

 