I Beam Variable Skew Angle
Applications
Right angle support
Butt members together and attach I Beam Variable Skew Angle with 6/No.12 Type 17 Hex Head Screw in each member. Ensure adequate end distance is achieved by having long edge fixed to butt end.
Minimum timber edge distance for screws = 30mm
Minimum timber end distance for screws = 60mm
Supporting at angle
Attach I Beam Variable Skew Angle to beam or girder truss with 6/No.12 Type 17 Hex Head Screw. Supporting member to be minimum 35mm deep. Notch out bottom of carried member 5 mm if required, and fit to I Beam Variable Skew Angle with 1/ Number 12 counter-sunk screw from underneath minimum 35mm long.
NOTES:
Do not over tighten screws
Pre-drill holes for hardwood
Capacities can be doubled for 2 angles if supported member is greater than 70mm thick
Right angle support
Supporting at angles
Supporting at angles
45° support angle
Product Specification |
Product Code | |
---|---|---|
I Beam Variable Skew Angle 75 x 50 x 150 x 5mm - 6mm Holes - HDG (Includes countersunk holes) | BALVSIA | |
I Beam Variable Skew Angle 75 x 50 x 300 x 5mm - 6mm Holes - HDG (Includes countersunk holes) |
|
Material Specification | |
---|---|
Thickness: | 5.0mm |
Material: | Hot dipped galvanised corrosion protection |